Maintenance Objects
1790
Issue 5 October 2002
1300
FAIL
The CSU Module/T1 Sync Splitter or the E1 Sync Splitter is missing.
The CSU Module/T1 Sync Splitter is missing: The
Near-End CSU Type
field on the add ds1 form has been administered as
integrated
but the
120A1 CSU Module or the 401A T1 Sync Splitter is not physically connected
to the UDS1 board on the back of the port carrier.
1. If using the 120A1 CSU Module or the 401A T1 Sync Splitter, plug the
CSU Module/T1 Sync Splitter into the UDS1 circuit pack’s connector on
the I/O connector panel on back of the carrier. Otherwise, change the
Near-End CSU Type
field using the change ds1 form to
other
.
2. Run the test again.
The E1 Sync Splitter is missing: The
E1 Sync-Splitter?
field on the
add ds1 form has been administered as
y
but the 402A or 403A E1 Sync
Splitter is not physically connected to the UDS1 board on the back of the port
carrier.
1. If using the 402A or 403A E1 Synchronization Splitter, plug the E1SS into
the UDS1 circuit pack’s connector on the I/O connector panel on back of
the carrier. Otherwise, change the
E1 Sync-Splitter?
field using
the change ds1 form to
n
.
2. Run the test again.
1301
FAIL
The 120A1 CSU Module or the 401A T1 Sync Splitter, or the 402A or 403A
E1 Synchronization Splitter is not expected.
The 120A1 CSU Module or the 401A T1 Sync Splitter is not expected: The
120A1 CSU Module/T1 Sync Splitter is physically connected to the UDS1
board on the back of the port carrier but the
Near-End CSU Type
field on
the add ds1 form has not been administered as
integrated
.
1. If the 120A1 CSU Module/T1 Sync Splitter is to be used, use the change
ds1 command to change the
Near-End CSU Type
field to
integrated
. Otherwise, physically remove the 120A1 CSU
Module/T1 Sync Splitter from the back of the port carrier.
2. Run the test again.
The 402A or 403A E1 Synchronization Splitter is not expected: The 402A or
403A E1 Synchronization Splitter is physically connected to the UDS1 board
on the back of the port carrier but the
E1 Sync-Splitter?
field on the
add ds1 form has not been administered as
y
.
1. If the 402A or 403A E1 Synchronization Splitter is to be used, use the
change ds1 command to change the
E1 Sync-Splitter?
field to
y
. Otherwise, physically remove the 402A or 403A E1 Synchronization
Splitter from the back of the port carrier.
2. Run the test again.
Table 530.
TEST #138 Loss of Signal Alarm Inquiry Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...