555-233-119
952
Issue 5 October 2002
If a DATA-CHL is busy but is not being used for one of these links, then it is being
used for a secondary administration terminal connection or for maintenance
testing. If it is being used for a secondary administration terminal connection, then
in order to test the DATA-CHL that the connection is using, the DATA-CHL must
be busied out using the busyout data-module <ext> command.
NOTE:
The busyout data-module <ext> command causes the connection over
the associated DATA-CHL to be dropped. Do not issue this command unless
instructed to do so.
If the DATA-CHL must be busied out in order to perform maintenance testing, the
secondary administration terminal connection must be re-established by redialing
the DATA-CHL.
CDR Links
1. Issue the status smdr-link command to see if an CDR Link has been
established. If the
Link State
field is
Up
, then the CDR Link may be
using one of the Data Channels (DATA-CHLs).
2. Issue the display system features command and go to the CDR
subsection on Page 2 of the resulting form. Note the values in the Primary
Output Extension and Secondary Output Extension fields. If the values are
extensions, then the CDR Link is using one of the Data Channels
(DATA-CHLs).
3. For each of the extensions in the Primary Output Extension and Secondary
Output Extension fields, issue the status data-module <ext> command
using the extension. Note the value in the Connected Ports field of the
resulting form. If there is a port value in the field, then the indicated port is a
Data Channel (DATA-CHL).
4. Issue the list data-module command, locate each port indicated in the
Connected Ports fields, and determine if that port has a “type” value of
“netcon.” If so, then there is an CDR Link over that DATA-CHL.
System Printer Links
1. Issue the status sp-link command to see if a System Printer Link has
been established. If the
Link State
field is
Up
, then the System Printer
Link may be using one of the Data Channels (DATA-CHLs).
2. Issue the display system features command and go to the System Printer
subsection on Page 2 of the resulting form. Note the values in the Primary
Output Extension and Secondary Output Extension fields. If the values are
extensions, then the System Printer Link is using one of the Data Channels
(DATA-CHLs).
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...