TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 5 October 2002
1649
555-233-119
Call State Audit Test (#257)
This test is nondestructive. This test performs a call state audit on an ISDN
B-Channel, and upon successful completion, guarantees that both sides of the
interface are in a consistent call state for connections using the B-Channel. The
test can be helpful when trying to clear a hung call. If the internal call state data to
the near-end switch is different from that of the far-end switch, the call will be torn
down.
The test passes if the audit is successful.
The test fails if the board is not inserted, there is an internal system error, or if a
reply was not received within a certain amount of time.
The test aborts if the signaling link is disconnected, the request is already active,
or if the B-Channel is in an Out-Of-Service state.
Table 484.
TEST #257 Call State Audit Test
Error
Code
Test
Result
Description/ Recommendation
1018
ABORT
The test is disabled.
1. Enable the test by entering y in the
Maintenance Tests?
field on
page 2 of the change trunk-group form.
1019
ABORT
An audit is already in progress.
1. Wait two minutes and try again.
1113
ABORT
The signaling link has failed, so the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Check).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1116
ABORT
The trunk is in an out-of-service ISDN service state.
1. A call cannot be present if the trunk is in an ISDN out-of-service state,
so a call state audit would be inappropriate. No action necessary. (Use
the status trunk command.)
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The audit passed successfully.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...