Maintenance Objects
1554
Issue 5 October 2002
RDIG-STA (Remote Digital Station)
A per-port instance of this maintenance object (RDIG-STA) is used to maintain the
circuitry associated with a port which has been translated as a digital station (or
DCP Console). The combo blade circuit board has the capability of having 24
instances of this type of maintenance object.
Remote Digital Station maintenance software provides maintenance for a port
administered as a digital station on the circuit pack. This strategy covers the
in-line errors log, initialization tests, periodic tests, craft-demanded tests, and
alarm resolution and escalation. Each port, translated as a digital station on a
digital line board, is running as a separate maintenance object (RDIG-STA) of this
type. Fault conditions discovered on one maintenance object may or may not
indicate faults on other maintenance objects of the same type.
Maintenance testing for the port circuitry on the combo blade circuit packs is
handled by on-board firmware and SPE (switch) controlled tests. Maintenance
software queries the firmware for error and alarm information, status, and test
results. Firmware automatically reports in-line error conditions, which results in
SPE-controlled testing.
There are instances where the service state of a station is mentioned. The
different service states that apply to a remote digital line station are as follows:
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier designation (A, B,
C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). pp is the two
digit port number (01, 02, etc.).
Full Name of MO
RDIG-STA
MINOR
test station UUCSSpp l
Remote Digital Station
RDIG-STA
WARNING
test station UUCSSpp sh
Remote Digital Station
Table 437.
Remote Digital Line Station Service States
Out-of-Service
The port, and thus the station, have been removed from service.
Busyout puts the port in the out-of-service state.
Ready-for-
Service
The port on the circuit pack has been put into service, but the voice
terminal has not yet established signaling communications with the port.
In-Service
The voice terminal has established signaling communications with the
port, and the system is ready to process calls to and from that station. A
terminal in the ready-for-service state will progress to the in-service
state if it is functioning normally. It can also be forced into the in-service
state by going off-hook.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...