display system-parameters maintenance
Issue 5 October 2002
257
555-233-119
DSO Loop-Around
Test Call
Extension
Extension number for the test call. This test extension number is
used to establish a loop-around connection on the selected trunk.
The DSO Loop-Around Test Call feature is used primarily for testing
DSO channels associated with non-ISDN-PRI trunks. The
loop-around is activated by dialing the test extension number.
Multiple DSO Loop-Around connections can be set up by placing
multiple calls to the loop-around extension.
The DS0 Loop Around feature provides a loop around connection for
incoming non-ISDN DS1 trunk data calls. This feature is similar to
the far-end loop around connection provided for the ISDN Test Call
feature. This DS0 loop around is provided primarily to allow a
network service provider to perform facility testing at the DS0 level
before video teleconferencing terminals are installed at the PBX.
The feature is activated on a call-by-call basis by dialing a test call
extension specified on the second page of the System Parameters
Maintenance form. No special hardware is required. When the test
call extension is received by the PBX, a non-inverting, 64 kbps
connection is set up on the PBX’s Time Division Multiplexed bus.
More than one loop around call can be active at the same time.
For calls routed over the public network using the ACCUNET
Switched Digital Service (SDS) or Software Defined Data Network
(SDDN), the data transmission rate is 56 Kbps, since robbed bit
signaling is used. For calls established over a private network using
common channel signaling, the full 64 kbps data rate is available.
When the incoming trunk group is used only for data calls (SDS), the
Communications Type on the associated Trunk Group form should
be set to “data.” When the incoming trunk group is used for robbed
bit alternate voice and/or data (SDN/SDDN), the Communications
Type on the Trunk Group form should be set to rbavd (robbed bit
alternate voice data). For private network trunks using common
channel signaling, the Communications Type on the associated
Trunk Group form can be set to “avd.”
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...