TIE-DS1 (DS1 Tie Trunk)
Issue 5 October 2002
1691
555-233-119
1005
ABORT
Test failed due to incompatible configuration administered in trunk group
form.
1. Verify the following fields on the trunk group administration screen:
a. Is trunk direction incoming only?
b. Is trunk outgoing type either automatic or immediate-start?
c. Is trunk the 24th port of the DS1 Interface circuit pack while
common control channel signaling is specified?
2. If the trunk has been administered using the above information, then
this test should abort.
1018
ABORT
The test was disabled via translation. You may want to determine why the
test has been disabled before you enable it.
1. Verify that the
Maintenance Test
field on the Trunk
Administration screen is set to n. To enable the test, change the trunk
administration and enter y into the
Maintenance Test
field.
2. Repeat the test.
1020
ABORT
The test did not run due to an already existing error on the specific port or
due to a more general circuit pack error.
1. Examine the error log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2. Retry the test.
1040
ABORT
This test is not performed for trunk ports administered as access endpoints.
1. Verify this port is an access endpoint by using the display port
command.
2. If the port has been administered as an access endpoint, this test
should abort.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2053
ABORT/
FAIL
1
At least one of the following errors is found on the circuit pack: 1281: Loss
of Signal, 1793: Blue Alarm, 2049: Red Alarm, 2305: Yellow Alarm, 1537:
Hyperactivity.
1. Look for the above error types in the Hardware Error Log and follow the
procedures given in the DS1-BD tests for the listed error types.
Table 499.
TEST #136 DS1 Tie Trunk Seizure Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...