ABORT
The port was seized by a user for a valid call. Use the display port
PCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. Wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1005
ABORT
Test inapplicable to present configuration. This is a normal condition.
1018
ABORT
Test has been disabled via administration.
1. Verify that the
Maintenance Tests
field on the Trunk Group Form
is set to n. To enable the test, issue change trunk-group x command
where x equals the number of the trunk group to be tested. Set the
Maintenance Tests
field to y.
2000
ABORT
Response to the request was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 162.
TEST #3 CO Demand Diagnostic Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...