Maintenance Objects
555-233-119
826
Issue 5 October 2002
k. This error occurs whenever the point-to-point signaling link to the endpoint
goes down (except when it goes down because either the PKT-CTRL or
the PKT-BUS has failed or has been busied out by system technician).
When this error occurs, an alarm is raised against the endpoint or adjunct.
Use test station <extension> short and look at the results of the
Signaling Link Status Test (#626). If this test fails, follow the repair
procedure for Test #626. The alarm is retired when the signaling link is
reestablished to the endpoint or adjunct.
l. Certain ASAI protocol-specific cause codes are logged by switch software.
The cause code can be determined from the following formula:
If the error type is greater than 3712, the ASAI cause code is equal to the
error type minus 3712. This code was sent to the adjunct by the switch.
If the error type is less than 3712, the ASAI cause code is equal to the error
type minus 3584. This code was sent to the switch by the adjunct.
A description of the various ASAI cause values is contained in the Table
10-64. This table also contains recommended system technician actions
associated with the cause value. Further information can also be found in
the ASAI Specification (288-500-03). In addition, the Aux Data field of the
Error Log entry contains additional diagnostic information.
Table 122.
ASAI Cause Values
Code
Explanation
Recommendation
Service or Option
Not Available
0
Unrecognized
ASAIProtocol
Operation
Requested ASAI protocol operation is not implemented by the switch
or adjunct. Aux Data field of Error Log entry contains protocol identifier
for unrecognized operation.
1. Consult switch and adjunct documentation to determine which set
of operations is supported by the switch and the adjunct. Adjunct
administration turning off operations not implemented by the
switch may resolve the problem.
40
Resources not
available
No available internal resources to service switch or adjunct request.
System transaction capacity for adjunct or switch is exceeded.
1. Re-engineering of adjunct services my be required.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...