Maintenance Objects
1558
Issue 5 October 2002
Demand Download Actions
1. Busyout/Release Command
A maintenance demand busyout/release request for a station will cause the
terminal to be downloaded regardless of its previous download status.
2. Feature Access Code
A Refresh Terminal Parameters Feature Access Code can be used to
request a terminal download action. When this code is followed by a “#”,
the programmable parameters for the current terminal are downloaded
when the terminal goes on-hook. When this code is followed by an
extension, the programmable parameters for the specified station are
downloaded.
This Refresh Terminal Parameters Feature Access Code is assigned on
the second page of the feature-access-codes screen.
A confirmation is returned if the download request is accepted. A busy tone
is returned if the request is made from a different station when the target
station is off-hook.
As a result of an entry of a Refresh Terminal Parameters Facility Access
Code, the first three green call appearance LEDs on the 84xx 603x
terminal are turned on for three seconds, if the station was successfully
downloaded. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or demand
download actions. As described below, the status station and status
attendant screens can be used to check the download status of a specified
terminal.
Status of Parameter Downloads
The status station and status attendant screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the
Download Status
field. The possible download states are:
Possible reasons for no terminal download include:
■
Terminal is off-hook
■
Terminal detected a bad checksum
■
Terminal detected a bad or missing EEPROM (refer to hardware error log)
■
Terminal is busy programming data from a previous PROGRAM message
Status
Terminal Download State
Complete
The terminal successfully downloaded sometime in the past.
Pending
The system is waiting to download the terminal. This may require the
execution of a background periodic test which could take more than an
hour. A demand download as described above may also be used to
initiate an immediate download.
Not Applicable
Not a programmable terminal.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...