ATM-BCH (ATM B-Channel Trunk)
Issue 5 October 2002
731
555-233-119
c. Error Type 129: the far-end switch changed its ISDN service state to either
out-of-service or maintenance. This may be a temporary condition because
the far-end is testing that trunk or a hardware problem with the trunk.
Outgoing calls may not be allowed over that trunk.
1. Investigate the trunk status (status trunk grp#/mbr#).
d. Error Type 130: the circuit pack has been removed or has been insane for
more than 11 minutes.
1. Reinsert or replace the circuit pack to clear the error.
e. Error Type 257: SETUP received for a B-channel that is in an invalid
service state. Service states may be incompatible at the two ends of the
trunk. A normal call was received while the B-channel was MTC/FE,
MTC/NE, OOS/FE, or OOS/NE or a test call was received while the
B-channel was OOS/FE or OOS/NE.
f. Error Type 513: RELease COMplete message received with cause value
82 (nonexistent channel). The B-channel may not be administered at the
far end. The trunk has been placed in the OOS/FE state.
g. Error Type 769: inconsistent SERVice or SERVice ACKnowledge
message. Possible causes:
■
SERVice or SERVice ACKnowledge message received containing a
change status that is more available than the previously-transmitted
SERVice message.
■
Unsolicited SERVice ACKnowledge message received containing a
change status that does not match the current B-channel state.
ISDN-PRI service-state negotiation rules have been violated and may
indicate that a pending service-state audit is failing. The system
■
cancels the maintenance timer
■
increments the Service State Audit counter
■
attempts a Service State Audit
When running the Short Test Sequence, pay close attention to the results
of the Service State Audit Test (#256).
h. Error Type 1793: TN230x circuit pack has failed. The maintenance system
■
places the trunk in the OOS/NE state
■
sends a SERvice message to the far-end (if possible) containing a
change status of OOS for the B-channel
■
returns the trunk to service when the ATM trunk circuit pack reports
the failure cleared
i. Error Type 3073: Service State Audit attempt failed (see Test #256). Calls
can be received but not placed until the test passes and the trunk state
returns to In-Service.
1. Check the trunk status (status trunk grp#/mbr#).
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...