TDM-CLK (TDM Bus Clock)
Issue 5 October 2002
1669
555-233-119
Notes:
a. The Tone-Clock circuit pack may have a clock at the edge of its specified
frequency. This can is turn cause Remote Neighbor Links (RNLs) and/or
Local Neighbor Links LNLs) to go down. When this error is alarmed, Clock
Health Inquiry Test (#46) will fail with an error code of 1.
1. Replace the Tone-Clock circuit pack identified in the error log.
b. The indicated Tone-Clock circuit pack has been made unavailable via the
busyout tone-clock PC command. To resolve this error, execute the
release tone-clock PC command for the alarmed circuit pack.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. The Tone-Clock circuit pack in the PPN is not a TN780 while a Stratum 3
synchronization is administered. Replace the Tone-Clock in the PPN with a
TN780, or change synchronization administration to Stratum 4 if a Stratum
3 clock is not being used.
e. The tone-clock has reported an out-of-lock condition. A aux value of 1
indicates this error is an out-of-lock with the primary reference. A aux value
of 2 indicates this error is an out-of-lock with the secondary reference. It
could not lock onto the frequency of that synchronization reference. This
will lead to a change in the synchronization reference if the condition
continues.
2049(i)
Any
Standby Reference
Health Check
Test(#651)
MAJOR
3
ON
test tone-clock PC
2305(j)
0
None
WARNING
OFF
1.
As a general rule, any on board errors against the TDM Bus Clock should be resolved before
pursuing any other errors against SPE or PNC components. Off board clock errors may be caused
by other board errors, and should usually be addressed once any on board errors have been
resolved.
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
3.
Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the
values used in the set options command.
Table 490.
TDM Bus Clock Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
1
Test to Clear Value
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...