
download update-file
Issue 5 October 2002
265
555-233-119
Feature Interactions
■
The form displayed for list configuration software-vintage reflects the
changes imposed by the flash architecture. The list configuration
software command allows INADS to determine with one query the
hardware configuration, software vintage, and patch identifier.
■
There is no interaction with routine periodic or scheduled maintenance,
because patches are only applied on restarts before the system is in
normal operation.
■
The flash checksum test acts as a backup check to ensure that the entire
field update file was applied correctly. It can fail because of a bad
checksum update from a poorly constructed update file or because the
patching operation has aborted. When the flash Checksum Test fails, a
MAJOR on-board alarm is raised on the processor/memory circuit pack.
■
When checking the software, the test compares the memory resident
software version and patch identifier. It also checks for the presence of a
field update file and, if found, compares the old and new patch identifiers to
make sure the same patch file id loaded on each processor. If the software
or update files are inconsistent, use list configuration software to display
the status of the patch file.
Recovery procedures
In the event of a failure encountered during the download and application of the
update file, follow the recommended recovery procedures.
Error on the download transmission
If the error displayed on the terminal indicates that the download step in the
process failed, there are several culprits:
1. The transmission line could have been noisy. Retry after making all the
following checks. Failed attempts take up room in the hard patch file and
may require a warm start to clear the file.
2. The user may have downloaded the tape/MIPS version of the patch
instead of the flash version.
3. The vintage of the update file may not match the vintage of software
currently running in the system. Check the customer’s vintage using list
configuration software and patch vintage provided in the documentation.
4. The system may have had difficulty in writing to the hard patch file. Check
the hardware error log for processor/memory board failures.
5. The hard patch file may be full. Issue a reset system 1. This should cause
valid files to be applied and invalid ones to be erased.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...