e. The circuit pack cannot update and read back NPE/NCE memory. This
error can be ignored, but may lead to other errors against this circuit pack.
f. The TN2185 board notifies maintenance software that it has detected a
parity error while accessing its dynamic RAM (that stores the board’s
translation information and downloadable application firmware).
Maintenance software resets the circuit pack.
g. Unable to write LAN Translation RAM Error (internal memory access error).
Translation RAM locations for the call connection attempt are not available,
and one or more RAM locations are bad due to a translation RAM
read-back error. Reset the circuit pack with the busyout board PCSS and
reset board PCSS commands. If the Circuit Pack Restart Test (#594)
passes, then the on-board circuitry is healthy. Retire the alarm with the test
board PCSS long clear command. If the Circuit Pack Restart Test (#594)
fails, replace the circuit pack.
h. Frame overrun at Packet Bus interface. Due to an on-board fault or by
faulty data received on one of the circuit pack’s external ports. If any of the
ports on this circuit pack is alarmed, refer to the repair procedures for those
maintenance objects. If this error persists, maintenance software removes
the board from service; replace the circuit pack.
i. The circuit pack is has problems transmitting/receiving data to/from the
Packet Bus.
1793
Parity errors are detected when transmitting data to the
Packet Bus.
1794
Packet Bus transmit buffers overflow.
1795
Circuit pack cannot find end of frame when transmitting to
Packet Bus. Clear the alarm with: busyout board PCSS,
reset board PCSS, test board PCSS long clear, release
board PCSS. If the error recurs within 10 minutes, replace
the circuit pack.
2306
Error in a received frame from the Packet Bus, most likely
caused by a packet bus problem, but may be due to a circuit
pack fault. An invalid Link Access Procedure Data (LAPD)
frame error occurs if the frame contains a bad Cyclical
Redundancy Check (CRC). If bus parity errors occur, run the
LAN Receive Parity Error Counter Test (#595) to determine if
the condition has cleared. Refer to the maintenance
documentation to determine if the problem is isolated to this
circuit pack or is caused by Packet Bus faults.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...