display system-parameters maintenance
Issue 5 October 2002
253
555-233-119
Field descriptions
Product
Identification
10-digit number, starting with 1, that identifies the switch to an
Operations Support System (OSS), for example, INADS.
First OSS Telephone
Number
First telephone number that the switch dials to report alarms;
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (# and * are not allowed in the telephone
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the first OSS.
(Default is y.)
Second OSS Telephone
Number
Second telephone number that the system dials to report
alarms; must be obtained from the National Customer Support
Center (NCSC) or the TSC. (# and * are not allowed in the
telephone number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the second
OSS. (Default is n.)
Alarm Origination to
OSS Numbers
Default is neither. Before Release 5, the name of this field is
Alarm Origination Activated.
■
both = all Major and Minor alarms result in an automatic
call to both OSS telephone numbers. Both OSS telephone
numbers must be administered.
■
first-only
= all Major and Minor alarms result in an
automatic call to the first OSS number. The system does
not call the second OSS telephone number even if the
number is administered. The first OSS telephone number
must be administered
■
neither
= alarm origination does not take place. Warning
alarms are not reported to either numbers.
■
second-as-backup
= all Major and Minor alarms result in
an automatic call to the first OSS telephone number. If
calling the first OSS telephone number fails four attempts,
the system starts to call the second OSS telephone number
as a backup until calling the first OSS telephone number
becomes successful. Both OSS telephone numbers must
be administered.
If Alarm Origination is deactivated, both Cleared Alarm
Notification and Restart Notification are disabled, even though
they may still be activated in the administration.
Cleared Alarm
Notification
Enables the system to originate a call to the OSS and send an
alarm resolution message whenever all previously-reported
Major and Minor alarms are resolved. Alarm Origination must
be activated in order for Cleared Alarm Notification to work.
Default is n.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...