Maintenance Objects
555-233-119
680
Issue 5 October 2002
1018
ABORT
Test has been disabled via administration. The default for the
Test
field on
the Station screen is y. Determine why this field has been set to
n
for this
station. It may be due to application Test #48, which can disturb users or
terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Test
field to y.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
System resources required to run test are not available. This could be due to
a failure to seize the port.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
This test can fail due to on-board or off-board problems. Off-board problems
include TDM-BUS faults, EXP-PN and EXP-INTF faults, and faults
associated with the tone detectors/tone generators. Clear all off-board
problems before replacing the board.
1. A TDM-BUS problem is usually the result of a faulty board connection to
the backplane, or bent pins on the backplane. Resolve any TDM-BUS
errors in the error log.
2. Resolve any EXP-PN and/or EXP-INTF errors in the error log.
3. Resolve any TONE-BD and/or TONE-PT errors in the error log.
4. Test the board when the faults from Steps 1, 2, and 3 are cleared.
Replace the board if the test fails.
PASS
The port is correctly using its allocated time slots. Investigate user-reported
troubles on this port by running other port tests, by examining station wiring,
or by inspecting the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use list
configuration and resolve any problems.
2. If the board is correctly inserted, use busy board UUCSS.
3. Issue reset board UUCSS.
4. Issue release board UUCSS.
5. Issue test board UUCSS long. This re-establishes the link between the
internal ID and the port.
6. If this is not the case, check to make sure that a valid board is inserted.
Table 50. TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...