5. Verify the availability of the external SYS-PRNT output device as follows:
Make sure that the SYS-PRNT output device is on-line and
ready-for-service. Check the physical connectivity between the Data
Module and the SYS-PRNT output device or between the EIA port on the
backplane of the switch and the SYS-PRNT output device.
6. Verify that there are less than three active logins to the system. If this
condition exists, a login session must be terminated before the System
Printer Link can be established.
NOTE:
It is recommended that the System Printer Link be busied out before
executing maintenance tests over objects which compose the
System Printer Link. If the System Printer Link is busied out, then all
System Printer Link maintenance actions are deactivated.
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the System Printer Link.
b. A failure was encountered while attempting to set up the System Printer
Link. This attempt could have been initiated by either the Report Scheduler
software or link maintenance [automatic link retry or the as the result of a
Link Retry Test (#215) request]. The Aux Data field contains the following
diagnostic information to aid in the correction of the failure:
1. unavailability of system resources (too many active logins to the
system).
2. no data channels (DATA-CHLs) available on the Network Control
circuit pack (DATA-BD).
Table 464.
SYS-PRNT Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test sp-link
18 (a)
0
busyout sp-link
WARNING
OFF
release sp-link
257 (b)
1 to 6
Link Retry Test
(#215)
MINOR/
WARNING
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
OFF
test sp-link l
513 (c)
0
None
MINOR
OFF
test sp-link
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...