SYS-LINK (System Links)
Issue 5 October 2002
1605
555-233-119
Notes:
a. Error Type 13: indicates that the link went down. The link may have gone
down or never come up. Enter command status sys-link location and
check the value of the field
Faulted Path
. If the value is
default
, then
the link never came up. If the value is
present
, then the link came up and
went down.
Follow the Common Procedure described above. Wait for 3 min before
checking the link state. Repeat the procedure until there are no problems
with the components.
b. Error Type 257: indicates that the link has experienced uplink flow control.
Manifest effect of this error is that the end-point may be hyperactive. The
system link is alarmed if 4 or more errors of this type are detected within 10
minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
c. Error Type 513: indicates that the link has experienced downlink flow
control. Manifest effect of this error is that some information packets from
the packet interface board have been lost. The link is reset on first
occurrence, hence, Error 1025 will also be logged. The system link is
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
d. Error Type 772: indicates that the link experienced a temporary disconnect
due to excessive resets or state transitions. The effect of this error is that
the link is taken down and then brought up again. The system link is
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
e. Error Type 1025: This error indicates that the link has been reset. Manifest
effect of this error is that information packets queued at the time of reset
are been lost. The system link is alarmed if 20 or more errors of this type
are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above.
Clear errors and wait for 10 minutes.
1537 (g)
WARNING
OFF
test sys-link PCSSpp l cl
1793 (h)
WARNING
OFF
test sys-link PCSSpp l cl
2049 (i)
WARNING
OFF
test sys-link PCSSpp l cl
Table 462.
SYS-LINK Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...