ETR-PT (Enhanced Tone Receiver Port)
Issue 5 October 2002
1183
555-233-119
FAIL
Hardware audit failed.
1. Use list configuration carrier to get the board type and location. If the
board is TN744, then do Steps 2-4; if it is TN2182, do Steps 5-12.
2. Execute 3 commands: busyout board UUCSS, reset board UUCSS,
and release board UUCSS. Reset is required to reload RAM
associated with the TN744’s DSPs. This will take all 8 tone detector
ports out of service for a few seconds. Only 4 of the 8 would be out of
service due to the alarm. (There are 4 tone detectors on each of the
two DSPs.) Other than the unlikely potential of running out of tone
detector resources in the switch, there is no other effect when the
board is reset.
3. Test the board (test board UUCSS long).
4. If the test passes, terminate the repair process. If the test fails, replace
the board. Follow the procedures in TONE-BD.
5. Check to see if the board is duplicated (list cabinet and status
port-network on the affected port network.)
6. If the board is not duplicated, use test tone UUCSS long to resolve the
error. The long test resets the board and is required to reload on-board
RAM associated with the TN2182”s DSPs. The effect is that tone
detectors are taken out of service momentarily and tones are removed
from the TDM bus for about 10 seconds. This means no dial or touch
tones during this interval, which probably will not affect calls in
progress, but could cause a call origination to abort or cause a user to
not get dial tone when going off hook.
7. If all tests pass and the alarm does not resolve, retest (test tone
UUCSS long clear).
8. If the test passes, terminate the repair process. If it fails, replace the
circuit pack at the customer’s convenience. Follow the procedures in
TONE-BD.
9. If the board is duplicated, switch to the standby side (set tone).
10. Test the alarmed board (test tone UUCSS long). This resets the board
and is required to reload on-board RAM associated with the TN2182’s
DSPs.
11. If all tests pass and the alarm does not resolve, retest with test tone
UUCSS long clear.
12. If the test passes, terminate the repair process. If it fails, replace the
board. Follow the procedures in TONE-BD.
PASS
The ETR Port has passed the sanity inquiry.
Table 263.
TEST #43 Tone Detector Audit/Update Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...