INADS (INADS Link)
Issue 5 October 2002
1259
555-233-119
INADS Link Test (no test number)
The INADS Link Test attempts to place a call to INADS (in the background) to
verify the communications link to INADS. When the test inads-link command is
issued, the user immediately sees either the
Command successfully
completed
or
Command failed
message. When a previously run command is
entered, the user immediately sees either
Command successfully
completed
or
Command failed
. The
Command failed
message appears
when a previously run test inads-link command is in progress or the system has
active alarms which must be reported to INADS. The
Command successfully
completed
means the switch will start the attempt to call INADS in two minutes
(the test still runs even if Alarm Origination is disabled). The two-minute delay
allows a remote INADS technician time enough to hang up the call and thus free
up the INADS line so that the switch can call INADS back. As error conditions are
encountered, errors are logged against INADS. Error codes 1 through 9 can be
logged if the test result was
Command successfully completed
and Error
Codes 10 and 11 can be logged if the test result was
Command failed
. An error
is also logged against INADS if the call to INADS finally succeeds. The INADS
software (release 3.2 or later) recognizes this special “test inads” type of alarm
and automatically opens and then closes a trouble ticket which indicates that the
reason for the trouble ticket is a command is in progress or the system has active
alarms which must be reported to INADS. The
Command successfully
completed
means the switch will start the attempt to call INADS in two minutes
(the test still runs even if Alarm Origination is disabled). The two-minute delay
allows a remote INADS technician time enough to hang up the call and thus free
up the INADS line so that the switch can call INADS back. As error conditions are
encountered, errors are logged against INADS. Error codes 1 through 9 can be
logged if the test result was
Command successfully completed
and Error
Codes 10 and 11 can be logged if the test result was
Command failed
. An error
is also logged against INADS if the call to INADS finally succeeds. The INADS
software (release 3.2 or later) recognizes this special “test inads” type of alarm
and automatically opens and then closes a trouble ticket which indicates that the
reason for the trouble ticket is a test inads-link command. The trouble ticket
alarm contains a
TESTING INADS LINK
description field.
After entering the command, it may take as long a nine minutes for the switch to
place the call and for INADS to respond. The Error Log should be examined (use
the category inads) 10 minutes after successfully entering the command to
determine if the call was successful.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...