555-233-119
1180
Issue 5 October 2002
Tone Detection Verification Test (#42)
This test checks out a single ETR port in the touch-tone receiver mode MFC tone
detection/generation mode and general purpose tone detection mode. During the
first portion of the test, the touch-tone receiver mode is tested. Then general
purpose call progress and maintenance tones are tested and lastly MFC tones are
tested.
Table 262.
TEST #42 Tone Detection Verification Test
Error
Code
Test
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate all the resources needed for this test
OR there was an Internal System Error.
1
ABORT
The system could not allocate all the resources needed to test the tones.
1001
ABORT
The system was unable to put the ETR-PT in the appropriate mode to test
it.
1002
ABORT
The system could not allocate time slots for the test connection. This
situation could occur when the system is heavily loaded. If the system is not
heavily loaded, then test the TDM-BUS via the test tdm command. Refer to
TDM-BUS for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a Tone-Clock for the test connection. This
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
network where the test aborted. If so refer to the recommended
procedures for TONE-BD or TONE-PT.
2. If a new Tone-Clock has been inserted, allow about 1 minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABORT
Circuit Pack’s response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2006
ABORT
This abort code indicates that the active Tone-Clock circuit pack or a Tone
Detector circuit pack may not be functioning properly. On G3r V2 systems,
this abort can also be caused by a mismatch between the companding
mode administered for the system and that of the Tone Detector circuit
pack.
1. [G3r V2] Make sure that the companding mode of the system matches
that of the Tone Detector: mu-law for TN748; A-law for TN420.
2. Test the active Tone-Clock circuit pack in the port network with the test
tone-clock PC command and refer to the TONE-BD section for
failures.
3. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...