AN-LN-PT (Analog Line Port)
Issue 5 October 2002
679
555-233-119
1000
ABORT
System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system’s Music-On-Hold port when it is
off-hook, which it usually is.
1. Use display port UUCSSpp to determine the station’s extension.
2. Use status station extension to determine the service state of the
port.
3. If the port is in use, wait until the port is idle. Retry the command at
1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1001
ABORT
System resources required to run test are not available. This could be due to
a failure to seize the port.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or have time slots out-of-service due to
TDM-BUS errors.
1. Refer to “TDM-BUS” to diagnose any active TDM-BUS errors.
2. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals no more than 5 times.
3. If the test continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute intervals no
more than 5 times.
4. If the test continues to abort, escalate the problem.
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use display port UUCSSpp to determine the station extension.
2. Use status station extension to determine the service state of the
port.
3. If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
Table 50. TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...