Logging On/Off
Issue 5 October 2002
55
555-233-119
To remove Facility Test Calls Access Code:
1. Enter change feature-access-codes to display the Feature Access Code
screen.
2. Leave the
Facility Test Calls Access Code
field blank.
!
CAUTION:
No alarms report through the INADS interface if Alarm Origination is
disabled.
!
CAUTION:
A busied out resource is one that is out of service. Be sure to verify if a
busied resource needs to be released or if the resource should remain
busied out.
Screen 6.
Logoff Screen
To Display a Login
1. Enter display login [login name] and press
Enter
.
The following information for the login appears:
■
Name
■
Login type
■
Service level
■
Disable following a security violation value
■
Access to INADS Port value
■
Password aging cycle length
■
Facility test call notification and acknowledgment
■
Remote access notification and acknowledgment
Facility Test Call Administered
Remote Access Administered
Alarm Origination is currently disabled.
Active major or minor alarm detected; be sure to resolve it.
*** Busied out resource detected; verify if release is needed! ****
Proceed With Logoff: [n]
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...