DATA-CHL (Data Channel)
Issue 5 October 2002
973
555-233-119
40
2000
2003
2004
FAIL
In the case of Error Code 40, the Local Loop Back Test failed because the
data received over the connection did not match the data sent over the
connection (data was corrupted). In the case of Error Code 2000, 2003, and
2004, the Local Loop Back Test failed because the data looped over the
connection was not received (data was lost).
1. Determine which of the DATA-CHLs are in use for some other function
(that is, PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT,
PMS-LINK or secondary administration terminal connection) as
described previously in the
‘‘Status of Data Channels’’
section.
2. The most likely problem is that the target DATA-CHL is defective.
Busyout all functions that are using the Data Channels (DATA-CHLs).
!
CAUTION:
All functions must be busied out because Test #107 is destructive and
terminates all established connections over the DATA-CHLs.
3. Issue the test data-module <ext> long command for the target
DATA-CHL. Note the test results for Tests #107 and #108.
a. If the result of Test #107 is FAIL, then the Processor circuit pack is
defective.
1. Replace the Processor circuit pack at your earliest
convenience. After the Processor circuit pack has been
replaced, its Time-of-Day clock must be set using the set time
command.
2. Repeat the test.
b. If the result of Test #107 is PASS and the result of Test #108 is FAIL:
1. Although all DATA-CHLs are unusable, the SW-CTL is still
operational. Based on the customer’s use of DATA-CHLs,
replace the Processor circuit pack at the customer’s
convenience. After the Processor circuit pack has been
replaced, its Time-of-Day clock must be set using the set time
command.
2. Repeat the test.
Table 177.
TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...