Maintenance Objects
1744
Issue 5 October 2002
ADMTSC maintenance provides a strategy to verify that a far-end can respond to
an ISDN-PRI USER INFORMATION TSC heartbeat message, thereby indicating
that user to user signaling is functioning. In addition, maintenance can retrieve the
status of the ADMTSC’s connection state.
Since ADMTSCs are administered on a per signaling group basis, the health of an
ADMTSC also depends on the state of the D-channel or D-channel pair
administered per signaling group. Refer to ISDN-SGR (ISDN-PRI Signaling
Group) Maintenance documentation for details on ISDN-PRI NFAS and
D-channel Backup maintenance. The two administration commands for
ADMTSCs are as follows:
■
add signaling group #
■
change signaling group #
The two maintenance commands for ADMTSCs are as follows:
■
test tsc-administered signaling group #[/tsc index]
■
status tsc-administered signaling group #/tsc index
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. There is no Test to Clear Value for error types 3840-3967. The error types
provide the following additional data that may prove useful when tracking
down problems.
This error indicates that a TSC Heartbeat Inquiry Test was run on an Active
far-end Administered TSC from the switch. Upon receiving the heartbeat
message, the network communicated to the switch that the call reference
value is not currently in use on the ISDN interface. As a result, the error
was logged. Check the signaling group status of the D-channel or
D-channel pair via the status signaling-group <group> command for the
Administered TSC. Check the status of the Administered TSC via the
status tsc-administered command. Also check the administration of the
Administered TSC on the switch.
This error may only be affecting service for some DCS customers. Upon
receipt of this error condition, the switch tears down and re-establishes the
ADMTSC within 20 minutes.
b. The port field in the error log contains the signaling group number for
TSC-ADM errors.
ADM TSC Error Log Entries
Error Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
3840-3967(a)
tsc index #
test tsc-administered
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...