TONE-BD (Tone-Clock Circuit Pack)
Issue 5 October 2002
1721
555-233-119
Notes:
a. Error Type 1
This error indicates the circuit pack totally stopped
functioning or it was physically removed from the system.
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack is
removed/SAKI Sanity Test (#53) fails.
If the circuit pack is not present in the system, insert a circuit pack in the
slot indicated by the error to resolve the error.
If the circuit pack is present in the system, it is faulty and must be replaced.
See the preceding section,
‘‘How to Replace a Tone-Clock Circuit Pack’’
.
b. Error Type 18
The indicated Tone-Clock circuit pack has been made
unavailable via the busyout tone-clock PC command. This error applies
only to High or Critical Reliability systems (an active Tone-Clock may not
be busied out). To resolve this error, execute release tone-clock PC.
c. Error Type 23
The circuit pack has been logically administered but not
physically installed. Installing the circuit pack will resolve the alarm.
d. Error Type 125
A wrong circuit pack is inserted in the slot where this
circuit pack is logically administered. To resolve this problem, either
remove the wrong circuit pack and insert the logically administered circuit
pack OR use the change circuit-pack command to readminister this slot
to match the circuit pack inserted.
e. Error Type 126
The port network specified in the PORT field of the error
log entry booted up without a Tone-Clock circuit pack, or with a one that
cannot communicate at all with the system. The error is logged five minutes
after the port network is restarted. If no circuit pack is present, install one of
the proper code. If there is a circuit pack present, replace it. See the
preceding section,
‘‘How to Replace a Tone-Clock Circuit Pack’’
. If
replacement does not solve the problem, follow normal escalation
procedures.
f. Error Type 257
Τ
his error indicates transient communication problems
with this circuit pack. This error is not service-affecting and no action is
required.
g. Error Type 513
This circuit pack has an on-board hardware failure.
Replace the circuit pack using the procedure described in preceding
section,
‘‘How to Replace a Tone-Clock Circuit Pack’’
.
h. Error Type 769
This error can be ignored, but look for other errors on this
circuit pack.
i. Error Type 1025
This error is not service-affecting and no action is
required.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...