Maintenance Objects
1516
Issue 5 October 2002
10308
ABORT
The remote access port is busy. INADS is probably dialed into the switch.
1. Wait until INADS session is terminated and then re-enter the command.
10311
ABORT
Test #102 MTP Outpulse Relay Test failed.
1. Refer to Error Code 10204 of the MTP Outpulse Relay Test (#102) for
directions.
10304
FAIL
MTP reported test failure. The system is not able to reliably contact INADS
with alarm data. The system continues to provide good service.
1. If MTP Outpulse Relay Test (#102) is also failing, check for the
presence of the INADS trunk, and resolve any INADS trunk problems.
2. If Test #102 passes, the fault is on the Processor circuit pack. The
circuit pack should be replaced at your convenience.
PASS
MTP detected correct data through the loop back connection.
1. If the system cannot call INADS, or if INADS cannot contact the
system, check with the local Central Office for problems with the INADS
trunk, and verify that the INADS number is correct.
Table 412.
TEST #103 MTP Analog Loop Around Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...