test journal-printer
Issue 5 October 2002
565
555-233-119
test journal-printer
Use test journal-printer to run hardware diagnostics on the link between the
switch and one of the journal printer links. There are two types of journal printer
links: pms-log and wakeup-log. For general information on journal printer links,
see
‘‘busyout pms-link’’
. For information on what a journal printer is and does, see
‘‘status journal-link’’
.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
journal-
printer
pms-log
wakeup-
log
short
long
repeat
number
clear
schedule
Tests the link to the pms logging printer
(maintenance name = PMS-PRNT)
Tests the link to the wakeup logging printer
(maintenance name = JNL-PRNT)
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
series of both destructive and
nondestructive diagnostic tests.
Number of times each test in the sequence
is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm (if
any) is cleared or a single test in the
sequence fails.
1
Use the screen to schedule execution of
the command. The command is placed in
the command queue and is executed at
the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
2
Examples:
test journal-printer pms-log l
test journal-printer pms-log l schedule
test journal-printer wakeup-log r 2
test journal-printer wakeup-log r 2
schedule
test journ pm r 3
test journ pm r 3 schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
sequence
= short;
repeat = 1
See below
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...