Maintenance for CSI systems
555-233-119
98
Issue 5 October 2002
Administration
1. At the management terminal, enter change ds1 <location>. The “location”
is the DS1 interface circuit pack for which the loopback jack was installed.
2. Be sure the “near-end CSU type” is set to
integrated
.
3. Tab to the S
upply CPE Loopback Jack Power
field and enter
y
.
NOTE:
Setting this field to y informs the technician that a loopback jack is
present on the facility. This allows a technician to determine that the
facility is available for remote testing.
4. Enter save translation to save the new information.
DS1 Span Test
This test should only be performed after the DS1 circuit pack and the 120A2 (or
later) ICSU have been successfully tested using appropriate maintenance
procedures. The DS1 span test consists of 2 sequential parts. Each part provides
a result indicating if there is a problem in the CPE wiring. CPE wiring may be
considered problem-free only if the results of both parts are successful.
The first part of the span test powers-up the loopback jack and attempts to send a
simple code from the DS1 board, through the wiring and loopback jack, and back
to the DS1 board. Maintenance software waits about 10 seconds for the loopback
jack to loop, sends the indication of the test results to the management terminal,
and proceeds to the second part of the test.
The second part of the test sends the standard DS1 3-in-24 stress testing pattern
from the DS1 board, through the loopback jack, and back to a bit error detector
and counter on the DS1 board. The bit error rate counter may be examined at will
via the management terminal, and provides the results of the second part of the
test. The test remains in this state until it is terminated so that the CPE wiring may
be bit error rate tested for as long as desired.
1. Busy out the DS1 circuit pack by entering busyout board UUCCSS
(where UUCCSS is the cabinet, carrier, and slot number of the DS1 board).
2. At the management terminal, enter change ds1 <location> and verify the
near-end csu type
is set to
integrated
.
3. Change to page 2 of the DS1 administration screen and confirm that the
TX LBO field is 0dB. If not, record the current value and change it to 0dB
for testing. Press
Enter
to implement the changes or press
Cancel
to change
nothing.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...