w. Error 3902 is used to give status information on a One-Way Span Test. The
value in the Aux Data field indicates the status of the span test.
x. Error type 3999 indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
error type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If error type 1538 is not present, then
the circuit pack has not been taken out-of-service, but it has generated
50% of the messages necessary to be considered hyperactive. This may
be completely normal during heavy traffic periods. However, if this error
type is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in
Table 124
. By clearing
error codes associated with the NPE Connection Audit Test, for example, you may
also clear errors generated from other tests in the testing sequence
1
—
Test is currently running.
2
—
Test has failed because test could not be activated.
3
—
Test pattern was not received from the far end.
4
—
Test has been terminated.
Table 222.
System Technician-Demanded Tests: DS1-BD
Order of Investigation
Short
Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
test
ds1-loop
Command
D/ND
1
NPE Connection Audit Test (#50)
X
ND
Control Channel Loop Test (#52)
X
ND
Loss of Signal Alarm Inquiry Test
(#138)
X
X
ND
Blue Alarm Inquiry Test (#139)
X
X
ND
Red Alarm Inquiry Test (#140)
X
X
ND
Yellow Alarm Inquiry Test (#141)
X
X
ND
Major Alarm Inquiry Test (#142)
X
X
ND
Minor Alarm Inquiry Test (#143)
X
X
ND
Slip Alarm Inquiry Test (#144)
X
X
ND
Misframe Alarm Inquiry Test (#145)
X
X
ND
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...