Maintenance Objects
555-233-119
814
Issue 5 October 2002
2
FAIL
For the TN556 or TN2208, received a status of Level 1 Pending
Activation-Endpoint Active which indicates a problem with the BRI endpoint
or ASAI or adjunct, the wiring to the endpoint or adjunct, or the ISDN-BRI
port.
For the TN2198, received a status of Level 1 Pending Activation. U
interface up S/T interface down, which indicates a problem with the NT1 or
the wiring between the NT1 and the BRI endpoint (S/T interface).
1. As necessary, check and repair the wiring between the circuit pack and
the endpoint or adjunct. Execute test port PCSSpp and review the
results of the Level 1 Status Inquiry test to verify the repair. If this test is
still fails, go to Step 2.
2. For BRI endpoints, try replacing the BRI endpoint(s) connected to the
port. For ASAI or adjuncts, follow the recommended repair procedures
of the manufacturer for link communication problems. For the NT1,
follow the recommended repair procedures of the manufacturer. Then
execute test port PCSSpp and review the results of the Level 1 Status
Inquiry test to verify repair.
3
FAIL
Received a status of Level 1 Deactivated; the port is out-of-service.
1. Use status bri-port PCSSpp to verify that the service state of the port
is out-of-service. If the service state of the port is not out-of-service, go
to Step 2.
2. If the port has been placed out-of-service with busyout port PCSSpp,
try to release the port with release port PCSSpp. Then use test port
long PCSSpp, and review the results of Level 1 Status Inquiry test. If
this test is still fails, go to Step 3.
3. Use test port long PCSSpp and review the results of all the tests.
Follow the repair procedures for any tests that fail. Verify repair of the
problem with test port PCSSpp and by determining that the Level 1
Status test passes.
4
FAIL
For the TN2198 only:
Received a status of Level 1 Pending Activation, the NT1 has a loss of
power indicating a problem with the NT1.
1. For the NT1 follow the manufacturers recommended repair procedures.
2. Use test port PCSSpp, and review the results of the Level 1 Status
Inquiry test to verify the repair.
PASS
This test indicates that Level 1 is activated, or that software has taken the
port out of service.
Table 114.
TEST #621 Level 1 Status Inquiry —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...