Maintenance Objects
1658
Issue 5 October 2002
Procedure 2
This procedure removes and re-inserts port circuit packs; one or several at a time.
If all of the TDM Bus tests pass when the circuit pack is removed, but some of the
tests fail when the circuit pack is inserted, the circuit pack is the cause of the
problem and should be replaced. If some of the tests fail regardless of whether the
circuit pack is inserted or removed, the circuit pack is not the cause of the problem
(see Note). Repeat this procedure for each purple slot circuit pack in the Port
Network.
NOTE:
Of course, in a multiple failure situation, the circuit pack may be one cause
of the TDM Bus problem and there may be other failures that are causing
TDM Bus faults. Also, the circuit pack itself may not be the cause of the
problem, but the backplane pins may have been bent when the circuit pack
was inserted.
1. Remove port circuit packs which have failed the NPE Crosstalk Test (#6)
first. To find which circuit packs failed this test, display the Hardware Error
Log via the display errors command. Refer to the Maintenance
documentation of each port circuit pack that has port errors to check if any
error indicates the failure of the NPE Crosstalk Test.
2. If no circuit pack failed the NPE Crosstalk Test (#6), remove one or several
purple slot circuit packs.
3. Run the test tdm P command.
4. If any of the TDM Bus tests fail:
■
Check if the backplane pins in the removed circuit pack’s slot
appear to be bent.
■
If the backplane pins are bent, straighten or replace the pins,
re-insert the circuit pack, and do this procedure again for the same
circuit pack.
■
If the backplane pins are not bent, re-insert the circuit pack and do
this procedure for the next set of circuit packs.
5. If none of the TDM Bus tests fail:
■
Re-insert the circuit pack.
■
Run the test tdm system technician command.
■
If any of the TDM Bus tests fail, the re-inserted circuit pack is faulty.
Replace the circuit pack and do this procedure again for the new
circuit pack.
■
If none of the TDM Bus tests fail, then the problem has been fixed.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...