555-233-119
962
Issue 5 October 2002
1006
ABORT
(cont’d.)
1. Issue the list data-module command to determine if other DATA-CHLs
are administered. If no other CATA-CHLs are administered, administer at
least one at this time.
2. Determine if the target DATA-CHL is in use for some other function (that
is, CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the "Status of Network Control Data Channels" section. If so, check for
errors on the function that is using the DATA-CHL. If there are no errors,
there is a high probability that the DATA-CHL is not defective. Proceed
with the remaining steps only if it is necessary to completely test the
target DATA-CHL.
a. If a DATA-CHL is being used for a secondary administration terminal
connection, busyout that DATA-CHL.
b. Otherwise, if a DATA-CHL is being used for a PMS Link, busyout the
PMS Link.
c. Otherwise, if a DATA-CHL is being used for a Journal Printer Link,
busyout the Journal Printer Link.
d. Otherwise, if a DATA-CHL is being used for an CDR Link, busyout the
CDR Link.
e. Otherwise, if a DATA-CHL is being used for a System Printer Link,
busyout the System Printer Link.
3. Retry the command at 1-minute intervals a maximum of 5 times.
4. Restore any busied out CDR, System Printer, Journal Printer, or PMS
Link to service before moving on to another activity.
1016
ABORT
Resources for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018
ABORT
Test disabled via software patch.
2003
ABORT
Internal system error
2004
ABORT
Internal system error
1. Check the dial plan to make sure that the extensions of the data channel
are set up as local extensions rather than remote or UDP extensions.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Table 175.
TEST #109 Data Channel Remote Maintenance Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...