Maintenance Objects
1414
Issue 5 October 2002
MMI-SYNC
NOTE:
Refer to
‘‘Troubleshooting Multimedia Call Handling (MMCH)’’
in
Chapter 1
.
Each Port Network (PN) must have a TN787D or later MMI circuit pack assigned
as the Multimedia Interface (MMI) master synchronization source for that PN. If
one or more MMI circuit pack is administered in a PN, one MMI circuit pack is
designated as the master synchronization source for all MMI circuit packs within
that PN.
The MMI circuit pack generates a synchronization signal and puts that signal on
the TDM bus. Other MMI packs or any other circuit pack within a PN can listen to
this signal and “synchronize up” to it. The first MMI circuit pack inserted in a PN is
normally designated as the master. As subsequent MMI packs are inserted, they
are instructed to listen and synchronize to the time-slot of the master MMI. In the
unlikely case of an MMI losing this reference, an uplink message is sent from the
MMI circuit pack that lost the signal to maintenance, which also clears the “event”
counter on this MMI with a downlink message. This forces the MMI circuit pack to
return the current state of the synchronization signal. If the signal is still lost, then
the recovery algorithm is entered. Note that during this time, the MMI circuit pack
synchronizes to its internal clock, and there should be no service disruption. A
loss of synchronization is usually the result of a circuit pack failure. The
maintenance strategy is to switch the master source away from the bad pack to
another healthy MMI circuit pack within the PN.
A synchronization switch takes place if half or more of the MMI circuit packs in a
PN report a loss of synchronization. For example, a PN with two MMIs reporting a
loss of sync source switches immediately, three and four MMIs switch if two report
the loss, and so forth. A healthy MMI circuit pack becomes the master
synchronization source providing the signal on a new timeslot. The other MMI
circuit packs within the PN are instructed to listen to this new signal, and the old
master stops providing the signal and now listens to the new master MMI. If an
MMI is physically removed from the system, then the remaining MMIs report the
loss of synchronization. The first MMI with no alarms present becomes the new
master of that PN. Once a synchronization switch has occurred, another switch is
not allowed for 15 minutes to avoid hyperactive switching. If all the MMIs have
alarms, then no switch is made.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); and SS is the address of the slot in the carrier where the circuit pack is located (for example, 01,
02, etc.).
Full Name of MO
MMI-SYNC
MINOR
test board PCSS l r#
Multimedia Interface Circuit Pack
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...