Maintenance Objects
555-233-119
830
Issue 5 October 2002
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors associated with the circuit pack and port first. Clearing these
error codes first may also clear errors generated against the endpoint. When all
circuit pack and port errors have been cleared, and errors still exist against the
endpoint, always investigate errors in the order they are presented in the table
below. By clearing error codes associated with the Signaling Link Status Test, for
example, you may also clear errors generated from other tests in the testing
sequence.
Note:
a. Use test port long PCSSpp and look at the results of the BRI Port Local
LAN Loop Around Test to verify the repair.
69
Requested
Facility Not
Implemented
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine service
support.
Adjunct switch
error conditions
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and
the adjunct. See the CallVisor protocol reference manual.
Table 124.
System Technician-Demanded Tests: BRI-SET
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Signaling Link Status Test (#626)
X
X
ND
BRI XID Test (#628)
X
X
ND
BRI Layer 3 Query (#629)
X (a)
X (a)
ND
BRI Remote Loop Back (#627)
X (a)
ND
BRI Set Audits (#630)
X (a)
X (a)
ND
BRI Vendor ID Test (#631)
X (a)
ND
BRI Model/Vintage ID Test (#632)
X (a)
ND
Table 123.
ISDN-BRI Cause Values —
Continued
Code
Explanation
Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...