Maintenance Commands
555-233-119
224
Issue 5 October 2002
Seq Cnt
Sequence Count - This number indicates the order of errors logged
within a second for the time stamps associated with the first
occurrence and last occurrence of an error. This information is
displayed only if the high-resolution command line option is entered.
There may be gaps for the sequence numbers within a given second
since the last occurrence of an error may replace an existing entry
that had been assigned the missing sequence number. Gaps may
also appear in the numbers since sequence counts are also used with
software event information not shown in the hardware error log.
Last Occur
Displays the month, day, hour, and minute (and second if the
high-resolution command line option is used) of the most recent error.
Note: if the system is unable to retrieve the time of day when the error
occurred, a ‘dummy’ date will be stamped in the log and appears as:
00/00/01:07.
Err Cnt
Error Count - The total number of times that the error type has
occurred for this maintenance object. If the number of errors exceeds
3 digits, the system enters the number 256, which indicates that a
larger number of errors occurred, but could not be displayed correctly.
Err Rt
Error Rate - The average rate at which the errors have occurred from
the first occurrence to the present. If the number of errors exceeds 3
digits, the system enters the number 256, which indicates that a larger
number of errors occurred, but could not be displayed correctly.
Rt/Hr
Rate per Hour - An approximation of the rate that this error occurred
in the last hour.If the number of errors exceeds 3 digits, the system
enters the number 256, which indicates that a larger number of errors
occurred, but could not be displayed correctly.
Al St
Alarm Status - A character indicating the status of this MO in the error
and alarm logs. The allowed values are:
a
=
Active alarm entry
r
=
Resolved alarm entry
c
=
Resolved alarm entry as a result of the long “clear” option of
the test command
s =
Resolved alarm entry as a result of a software requested
(non-demand) system restart
t
=
Resolved alarm entry as a result of a technician requested
system restart
n
=
Not alarmed.
Ac
Active? - A y (yes) entry indicates the maintenance object is still
active. A n (no) entry indicates the object is no longer a problem.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...