555-233-119
1182
Issue 5 October 2002
Tone Detector Audit/Update Test (#43)
A Digital Signal Processor sanity audit is performed on the ETR-PT.
Table 263.
TEST #43 Tone Detector Audit/Update Test
Error
Code
Test
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate all the resources needed for this test.
1. Wait 1 minute, and repeat the command a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.