UDS1-BD (UDS1 Interface Circuit Pack)
Issue 5 October 2002
1791
555-233-119
1302
FAIL
Attempting to use the 120A1 CSU Module with a UDS1 circuit pack that is
configured for 32-channel (2.048 Mbps) operation. The CSU Module only
works with a DS1 board configured for 24-channel (1.544 Mbps) operation in
the United States of America.
1. If the 120A1 CSU Module is to be used, physically remove the UDS1
circuit pack and reconfigure for 24-channel (1.544 Mbps) operation.
2. Reinsert the circuit pack and run the test again.
1303
FAIL
The DS1 circuit pack Suffix is incorrect for CSU Module/T1 Sync Splitter or
E1 Sync Splitter administration.
The DS1 circuit pack Suffix is incorrect for CSU Module/T1 Sync Splitter
administration. The
Near-End CSU Type
field on the add ds1 form has
been administered as
integrated
but the DS1 circuit pack is not a
TN464F or later suffix UDS1 board.
1. If the CSU Module/T1 Sync Splitter is to be used, and the
Near-End
CSU Type
field is set to
integrated
to allow for CSU Module/T1
Sync Splitter administration, remove the circuit pack and replace it with a
TN464F or later suffix board. Otherwise use the change ds1 command
to change the
Near-End CSU Type
field to
other
.
The DS1 circuit pack Suffix is incorrect for E1 Sync Splitter administration.
The
E1 Sync-Splitter?
field on the add ds1 form has been
administered as
y
but the DS1 circuit pack is not a TN464F or later suffix
UDS1 board.
1. If the E1 Sync Splitter is to be used, and the
E1 Sync-Splitter?
field is set to
y
to allow for E1SS administration, remove the circuit pack
and replace it with a TN464F
or later suffix board. Otherwise use the
change ds1 command to change the
E1 Sync-Splitter?
field to
n
.
1310
FAIL
The DS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using the test ds1-loop UUCSS
ds1/csu-loopback-tests command.
2. If the BLB test continues to fail, then replace the UDS1-BD circuit pack.
3. Run this test again.
Table 530.
TEST #138 Loss of Signal Alarm Inquiry Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...