Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-243
Code
Problem Description
Troubleshooting
57AA800
Status of BMD inter lock
detachment before the
operation during Withdrawal.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
57AA900
Status of BMD removal before
the operation during
Withdrawal.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
57AAA00
Status of BC open before the
operation during Withdrawal.
1. Open the upper unit
2. Check the lock lever in the BC
57AAC00
Status of RJC full before the
operation during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
57AAD00
Status of UTC1 full before the
operation during Withdrawal.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
57AAE00
Status of UTC2 full before the
operation during Withdrawal .
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
57AAF00
Status of RC empty before the
operation during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
57AE100
Received operation command
without Initail Info Set during
Withdrawal .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
57AE200
Status on not operation
receiption command during
Withdrawal .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
57AE300
Received execute command
without Read System Info.
during Withdrawal .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
57AE400
Withdrawal transaction was
executed without Initializing
after power on.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
57AE600
Error to received Withdrawal
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization