Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-207
Code
Problem Description
Troubleshooting
570F700
Decreased encoder count of
GM004 moter less than
previous values during
Withdrawal .
1. Operate to initialize BRM(Recovery)
570G100
Failure to 3 Way Gate 0
degree mode conversion
during Withdrawal .
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
570G200
Failure to 3 Way Gate 120
degree mode conversion
during Withdrawal .
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
570K100
Erro of failure to duplicate
serial number during
Withdrawal
1. Check the duplicate note and remove
the note.
2. Operate to initialize BRM(Recovery)
570N700
GSx05 stack count error to
Return Notes under auto
recoveryduring Withdrawal
(Insert over 2 Notes into RC).
1. Operate to initialize BRM(Recovery)
570N800
Continous dark error on the
GSx05 to Return Notes under
auto recoveryduring
Withdrawal.
1. Operate to initialize BRM(Recovery)
570N900
Pick-up count did not match up
with stack count when
separate end in the Deposit
Cancel.
1. Operate to initialize BRM(Recovery)
570NC00
Failure to check the last note
at the termination of mid
transport path during
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
570Q100
UTC removal error during
Withdrawal .
1. Open the upper unit
2. Check removal of the cassette not
received(9)
570Q200
TE open error during
Withdrawal .
1. Open the upper Unit
2. Check open/close of TE(12)
570Q300
BMU inter lock error during
Deposit Count.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
570Q400
BMU removal error during
Withdrawal .
1. Check Load/Removal of the upper
unit
570Q500
Safe door open error during
Withdrawal .
1. Check the safe door open
570Q600
CSM open error during
Withdrawal .
1. Open the upper unit
2. Check to open/close CSM
3. Check the sensors GS011
570Q700
RJC removal error during
Withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
570Q800
BMD inter lock error during
Withdrawal .
1. Check the lower Unit load/removal
2. Replace a cherry switch when error
occures