Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-136
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
544G100
Failure of return notes to RC4
during Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
544G200
Failure to move stack position
of RC4 PP during Deposit
Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Open the recycle cassette door (D)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
544G400
Failure to upword moving of
PP during RC4 stack roller
retreat movement in the
Deposit Cancel .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Open the recycle cassette door (D)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
544G500
Failure to RC4 stack roller
retreat during Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Check the jam removal knob rotates
softly
544G600
Exceeds retry count limit of
detecting RC4 stack
roller´s falling back and
avoiding during Deposit
Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Check the jam removal knob rotates
softly
544G800
Failure to RC4 push pressure
movement during Deposit
Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Check the upper side of the recycle
cassette
544GA00
RC4 solenoid echo error
during Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Reload the recycle cassette (D) after
removing recycle cassette
4. Replace the cassette when same
error occurs