Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-59
Code
Problem Description
Troubleshooting
52AAC00
Status of RJC full before the
operation during Deposit
Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
52AAD00
Status of UTC1 full before the
operation during Deposit
Count.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
52AAE00
Status of UTC2 full before the
operation during Deposit
Count .
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
52AAF00
Status of RC empty before the
operation during Deposit
Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
52AE100
Received operation command
without Initail Info Set during
Deposit Count.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
52AE200
Status on not operation
receiption command during
Deposit Count.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
52AE300
Received execute command
without Read System Info.
during Deposit Count.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
52AE400
Deposit count transaction was
executed without Initializing
after power on.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
52AE600
Error to received deposit count
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
52AEE00
RBU RS485 communication
sequence disorder during
Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
52AEF00
RBU RS485 connection line
disorder during Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
52AH500
Error to
NVRAM(128denominations)
Read/ Write during Deposit
Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
52AN700
TE stack counts is different
with BC pass info of normal
count in the Deposit Count.
1. Operate to initialize BRM(Recovery)