Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-384
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D0F600
Decreased encoder count of
GM002 moter less than
previous values during
Initialize.
1. Operate to initialize BRM(Recovery)
5D0F700
Decreassed encoder count of
GM004 moter less than
previous values during
Initialize.
1. Operate to initialize BRM(Recovery)
5D0G100
Failure to 3 Way Gate 0
degree mode conversion
during Initialize.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5D0G200
Failure to 3 Way Gate 120
degree mode conversion
during Initialize.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5D0L100
Failure to GS801 notes
remains stack process error
during Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D0L200
Failure to GS002 notes
remains stack process error
during Initialize.
1. Open the upper unit
2. Open the Front Transport Path (4)
3. Remove the notes and the substance
from the Front Transport Path (4)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D0L300
Failure to GS003 notes
remains stack process error
during Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D0L400
Failure to GS004 notes
remains stack process error
during Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D0L500
Failure to GS005 notes
remains stack process error
during Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance