Code
Problem Description
Troubleshooting
5D4GF00
Detect both GS408(separate
pressure) and GS412(Bottom)
as excessive note durting
Initialize
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove note.
5D4GG00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Initialize.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5D4GH00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Initialize.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5D4J300
RC4 full check failure during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Check the stage status after open the
recycle cassette(D)
5. Check contamination status of the
GS412 sensor.
5D4R100
RC4 message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D4R200
RC4 message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D4R300
RC4 message timeout error
during postprocessing to
Initialize Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D4S100
Undefined return value of RC4
during Initialize.
1. Operate to initialize BRM(Recovery)
5D4S200
Undefined command of RC4
during Initialize.
1. Operate to initialize BRM(Recovery)
5D50500
GS505 Light Jam during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(18)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).