Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-437
Code
Problem Description
Troubleshooting
5HBS200
RBU connection MI error when
CST Set Notes Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5HUS100
USB sequence number
duplicate error when CST Set
Notes Count.
1. Restart over AP-SP
5HUS300
USB command data length
error when CST Set Notes
Count.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5J8HA01
Error GS801A during Stop
Ready.
1. Check GS801A
2. Operate to initialize BRM(Recovery)
5J8HA02
Error GS801B during Stop
Ready.
1. Check GS801B
2. Operate to initialize BRM(Recovery)
5J8HA03
Error GS801A, GS801B during
Stop Ready.
1. Check GS801A, GS801B
2. Operate to initialize BRM(Recovery)
5J8HA04
Error GS802A during Stop
Ready.
1. Check GS802A
2. Operate to initialize BRM(Recovery)
5J8HA05
Error GS801A, GS802A during
Stop Ready.
1. Check GS801A, GS802A
2. Operate to initialize BRM(Recovery)
5J8HA06
Error GS801B, GS802A during
Stop Ready.
1. Check GS801B, GS802A
2. Operate to initialize BRM(Recovery)
5J8HA07
Error GS801A, GS801B,
GS802A during Stop Ready.
1. Check GS801A, GS801B, GS802A
2. Operate to initialize BRM(Recovery)
5J8HA08
Error GS802B during Stop
Ready.
1. Check GS802B
2. Operate to initialize BRM(Recovery)
5J8HA09
Error GS801A, GS802B during
Stop Ready.
1. Check GS801A, GS802B
2. Operate to initialize BRM(Recovery)
5J8HA10
Error GS801B, GS802B during
Stop Ready.
1. Check GS801B, GS802B
2. Operate to initialize BRM(Recovery)
5J8HA11
Error GS801A, GS801B,
GS802B during Stop Ready.
1. Check GS801A, GS801B, GS802B
2. Operate to initialize BRM(Recovery)
5J8HA12
Error GS802A, GS802B
during Stop Ready.
1. Check GS802A, GS802B
2. Operate to initialize BRM(Recovery)
5J8HA13
Error GS801A, GS802A,
GS802B during Stop Ready.
1. Check GS801A, GS802A, GS802B
2. Operate to initialize BRM(Recovery)
5J8HA14
Error GS801B, GS802A,
GS802B during Stop Ready.
1. Check GS801B, GS802A, GS802B
2. Operate to initialize BRM(Recovery)
5J8HA15
Error GS801A, GS801B,
GS802A, GS802B during Stop
Ready.
1. Check GS801A, GS801B, GS802A,
GS802B
2. Operate to initialize BRM(Recovery)
5J8HF03
Error to load shading data of
the CIS during Stop Ready.
1. Operate shading in the BC CIS
2. Operate to initialize BRM(Recovery)
5J8HF04
Error to load recognition DB
table during Stop Ready.
1.Download DB again after delecting all
recognition DB
2. Operate to initialize BRM(Recovery)
5J8HF05
Error to BC FPGA data
checksum during Stop Ready.
1. Check to BC FPGA File
2. Operate to initialize BRM(Recovery)
5J8HF06
Error to BC FPGA
configuration during Stop
Ready.
1. Re-download BC FPGA
2. Change the BC B/D if continuous
error.
5J8HF07
Error to load to info of BC
FPGA header during Stop
Ready.
1. Re-download BC FPGA
2. Change the BC B/D if continuous
error.