Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-219
Code
Problem Description
Troubleshooting
5735500
Error occurred by the
Transport Path on the GS305
during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5736500
Error occurred by the Return
Transport Path(GS305) during
Withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5737500
Error occurred by the notes
disorder on the GS301 during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
573C100
RC3 mis-pickup during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check the upper and the Notes
573G100
Failure of return notes to RC3
during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance