Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-215
Code
Problem Description
Troubleshooting
572C100
RC2 mis-pickup during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check the upper and the Notes
572G100
Failure of return notes to RC2
during Withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
572G200
Failure to move stack position
of RC2 PP during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
572G300
Failure to PP stack roller
retratment position movement
during separate again from
RC2 separate during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
572G400
Failure to upword moving of
PP during RC2 stack roller
retreat movement in the
withdrawal .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
572G500
Failure to RC2 stack roller
retreat during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly