Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-250
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
58AA200
Status of TE open before the
operation during Notes Out.
1. Open the upper Unit
2. Check open/close of TE(12)
58AA300
Status of BMU inter lock
detachment before the
operation during Notes Out.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
58AA400
Status of BMU removal before
the operation during Notes
Out.
1. Check Load/Removal of the upper
unit
58AA600
Status of CSM open before the
operation during Notes Out.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011
58AA700
Status of RJC removal before
the operation during Notes
Out.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
58AA800
Status of BMD inter lock
detachment before the
operation during Notes Out.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
58AA900
Status of BMD removal before
the operation during Notes
Out.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
58AAA00
Status of BC open before the
operation during Notes Out.
1. Open the upper unit
2. Check the lock lever in the BC
58AE100
Received operation command
without Initial Info Set during
Notes Out.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
58AE200
Status on not operation
receiption command during
Notes Out.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
58AE300
Received operation command
without System Info Read
during Notes Out.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
58AE400
Notes Out transaction was
executed without Initializing
after power on.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
58AE600
Error to received Notes Out
transaction during TE Button
Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
58AEE00
RBU RS485 communication
sequence disorder during
Notes Out.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization