Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-333
Code
Problem Description
Troubleshooting
5B0F600
Decreased encoder count of
GM002 moter less than
previous values during Retract
TE.
1. Operate to initialize BRM(Recovery)
5B0F700
Decreassed encoder count of
GM004 moter less than
previous values during Retract
TE.
1. Operate to initialize BRM(Recovery)
5B0G100
Failure to 3 Way Gate 0
degree mode conversion
during Retract TE.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5B0G200
Failure to 3 Way Gate 120
degree mode conversion
during Retract TE.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5B0K100
Erro of failure to duplicate
serial number during Retract
TE
1. Check the duplicate note and remove
the note.
2. Operate to initialize BRM(Recovery)
5B0K200
Status of UTC1 and UTC2 full
during Retract TE.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
5B0N900
Pick-up count did not match up
with stack count when
separate end in the Retract
TE.
1. Operate to initialize BRM(Recovery)
5B0NA00
Checksum error when
separate TE notes from TE
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B0NC00
Failure to check the last note
at the termination of mid
transport path during Retract
TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B0Q100
UTC removal error during
Retract TE.
1. Open the upper unit
2. Check removal of the cassette not
received(9)
5B0Q200
TE open error during Retract
TE.
1. Open the upper Unit
2. Check open/close of TE(12)
5B0Q300
BMU inter lock error during
Retract TE.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
5B0Q400
BMU removal error during
Retract TE.
1. Check Load/Removal of the upper
unit
5B0Q500
Safe door open error during
Retract TE.
1. Check the safe door open
5B0Q600
CSM open error during Retract
TE.
1. Open the upper unit
2. Check to open/close CSM
3. Check the sensors GS011
5B0Q700
RJC removal error during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal