Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-440
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5J8HG24
Error of encoder set-up mode
during receiving BCU ready
command in the Stop Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5J8HG36
Error of recognized mode
during receiving BCU mode
command in the Stop Ready .
1. Check to the recoginzed mode
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
5J8HG37
Error of transaction setting
during receiving BCU mode
command in the Stop Ready .
1. Check to the transaction setting
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
5J8R900
BC message timeout error
during Stop Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5J8S100
Receive abnormal MI from BC
during Stop Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5J8S200
Receive abnormal BCC from
BC during Stop Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5J8S400
Receive ETC. error from BC
during Stop Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5J8S900
Receive retry error from BC
during Stop Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5JAE100
Received operation command
without Initial Info Set during
Stop Ready.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5JAE200
Status on not operation
receiption command during
Stop Ready.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5JAE300
Received operation command
without System Info Read
Command during Stop Ready.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5JAE400
Stop Ready transaction was
executed without Initializing
after power on .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization