Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-489
Code
Problem Description
Troubleshooting
5NAEE00
RBU RS485 communication
sequence error during CST
notes count Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5NAEF00
RBU RS485 connection line
error during CST notes count
Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5NAH500
Error to
NVRAM(128denominations)
Read/ Write during CST notes
count Read.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization.
5NBH100
RC1 EEPROM read error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH200
RC2 EEPROM read error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH300
RC3 EEPROM read error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH400
RC4 EEPROM read error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH500
RC5 EEPROM read error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH600
RC1 EEPROM write error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH700
RC2 EEPROM write error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH800
RC3 EEPROM write error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBH900
RC4 EEPROM write error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBHA00
RC5 EEPROM write error
when CST notes count Read.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5NBHB00
RC1 EEPROM data verify
error when CST notes count
Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization